| Offering you a complete choice of products which include Addressable Fire System GST such as Fire Protection System, GST Intelligent Smoke Detector, Intelligent Ultraviolet Flame Detector, Addressable Sounder, Addressable Sounder Base, Addressable Multi Sensor and many more items. |
Fire Protection System |
|
We offer Addressable 1 Loop Fire Panel GTS-100 or Fire Protection System.
|
GST Intelligent Smoke Detector |
|
GST Intelligent Smoke Detector is the ideal device for most application due to its excellent linear response to a wide variety of different type of smoke patterns. The unit meets the sensitivity requirement of UL 268 Standard for Smoke Detector for Fire Protective Signaling System Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Drift compensation, Self Diagnosis and history log. The integral microprocessor analysis the signal according to the factors such as signal strength and rate of increase, then confirms these pattern with the pre-programmed fire scenarios and smoke patterns for a faster and safer response. By intelligent analysis, the smoke detection sensitivity will be automatically adjusted according to temperature change, providing a rapid response. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Drift compensation, to monitor for the long term changes caused by aging, humidity, temperature, dust, etc. constant monitoring and self adjusting, the I-9102 UL updates sensitivity base line for its sensing element. Even when the detector raises a warning advising that it requires cleaning, the sensitivity remains the same as the day it was installed. Electronic addressing can be done through Handhold Programming device (P-9910B), purchased separately.
|
Intelligent Ultraviolet Flame Detector |
|
Item Code: I-9103 The I-9104 Intelligent Ultraviolet Flame Detector is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance,used in high hazard applications such as petrochemical plants,munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The I-9104 sensor provides an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion-proof and moisture-resistant. The sensor is not sensitive to sunlight, dust,oil, fume, and humidity. Set as a standard calibration to detect a 3cm flame at a distance of 6 meters with a total effective range of 12 meters. Has unique electronic addressing to provide specific location,information and monitor condition. The integral microprocessor analyses the signal according to the factors such as signal strength and rate of increase, then confirms these pattern with the pre-programmed fire scenarios and flame patterns for a faster and safer response. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Electronic addressing can be done through Handhold Programming device (P-9910B), purchased separately
|
Addressable Sounder |
|
Item Code: I-9404
We offer Addressable Sounder. Technical Specifications:
|
Addressable Sounder Base |
|
Item Code: I-9402 Addressable Sounder Base includes 2 parts, fire detection and control. In case of fire comes, the sounder will be the most effective device to wake up the person and evacuate the building. For special buildings like hotel, the room is isolated by thick wall and heavy door,alarm sound can not easily reach the bedroom. So local alarm devices needed. GST developed sounder base to achieve the above function. Electronic addressable and loop powered, convenience to use. Two addresses to make sounds of ALERT and EVACUATE. With start signal from FACP through the loop, I-9402 can be controlled by program, making ideally order of evacuating. Those under base can be used as a common base with GST intelligent detector or stand alone with a cover. Electronic addressing can be done through Handhold Programming device (P-9910B), purchased separately.
|
Addressable Multi Sensor |
|
Item Code: I-9101 Addressable Multi Sensor all the features of the I-9102 Optical and the I-9103 Dual Heat Detectors the unit provides an ideal solution for life and safety systems. Ideally suitable for application in data processing area including telephone exchange, conference rooms, indoor markets or shops, dining area, factory, recording studio and libraries etc. Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Drift compensation, Self Diagnosis and history log. The integral microprocessor analyses the signal according to the factors such as signal strength and rate of increase, then confirms these pattern with the pre-programmed fire scenarios and smoke patterns for a faster and safer response. By intelligent analysis, the smoke detection sensitivity will be automatically adjusted according to temperature change, providing a rapid response. Secure and speedy communication through the on board process or enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Drift compensation, to monitor for the long term changes caused by aging, humidity, temperature, dust, etc. constant monitoring and self adjusting, the I-9101 updates sensitivity base line for its sensing element. Even when the detector raises a warning advising that it requires cleaning, the sensitivity remains the same as the day it was installed. Electronic addressing can be done through Hand held Programming device (P-9910B), purchased separately. Intelligent Multi SensorI-9101
|
Addressable Zone Monitor Module |
|
Item Code: I-9319
-- @page { size: 8.5in 11in; margin: 0.79in } I-9319 intelligent zone monitor unit is an Addressable Zone Monitor Module, which will integrate conventional detectors or conventional manual call points to addressable system. When any of the connected devices alarms are active, the unit can send the alarm message to fire alarm controller, which generates alarm signal and displays its address. The unit can match with the conventional optical smoke detector, conventional rate of rise and fixed temperature detector and conventional manual call point etc. It has the function of checking short or open circuit of the output connection, by the End of Line Resistor (EOLR) or Active End of Line unit (AEOL recommended). The fault massage includes open circuit, short circutor any removal of the detectors. Electronic addressing can be done through Hand held Programming tool (P-9910), purchased separately.
|
Repeater Panel GST-NRP01 |
|
-- @page { size: 8.5in 11in; margin: 0.79in } GST-NRPO1 Network LCD Repeater Panel is designed to control and reset the alarm remotely and display fire, fault, action and supervisory. This repeater panel can display the location numbers and information of the detectors and sends out audible and optical signals. Through RS485 communication network the repeater can be connected to all GST Intelligent fire alarm controllers. Compact size and easy to install. The repeater can be used whenever there is a need to relay information to multipoint informing key personnel. Networking Selection of Compatible panels Compatible with all GST Intelligent fire alarm panel. Network Repeater Panel GST-NRP01
|
Intelligent Input Module |
|
Item Code: I-9300 I-9300 Intelligent Input Module is used to receive normally open or normally closed control signals from interfaced equipment, and transmit the messages back to fire alarm control panel. The units ideal for use in water flow indicator, pressure switch, position switch,signal valves and external interface devices. When these devices operate, the output signal can be transmitted to fire alarm control panel via the module through the fire alarm loop to generate alarm, and activate other relevant devices. Electronic addressing can be done through Hand held Programming tool (P-9910B), purchased separately.
|
Addressable Sounder Beacon |
|
Addressable Sounder Beacon for fire, security, school sand industrial area. The I-9401 is designed to meet the requirement of EN54The unit is utilised a red Plexiglas cover and a number of strong signal red LED, long-life and low consumption. Two part construction with base mounted termination allows easy installation and avoiding the wiring and connection problem associated with traditional sounder. Electronic addressing can be done through Handhold Programming device (P-9910), purchased separately.
|
Addressable 8 Loop Fire Panel |
|
Item Code: GST-IFP8
The Addressable 8 Loop Fire Panel . Flush mounted type housing it provides the perfect solution for all medium to large system by utilizing advance GST Protocol. The system is compatible with the complete range of GST Intelligent detectors, Sounders, Call Points, and Interfaces, including intrinsically safe and gaseous extinguishing control. IFP8 is manufactured and certified to EN54 parts 2 and 4 and to BS5839 Par 4. The GST programming facilities enables advanced and complex cause and effects to be programmed with ease, including phased and cascade evacuation scenarios. With added commission features such as duplicate address checking, device mismatch and editing device detailed and programmed through the control panel makes the task of commissioning engineer very simple. By utilizing the GST protocol the GST-IFP8 can be networked with up to 64 panels, programmable to One system or Sub-panel operation, not only the GST200/2 loop panel, but also with the GST5000/2/4 Loops panel and the GST5000 modular 20 panel, making this the perfect solution for large decentralized systems such as Shopping Centers Military campus industrial complexes, Holiday villages etc. With up to 2,420 two-wire fire alarm linkage control points that can also be intelligent be connected with many serial products (ex. digital detector, analogue detector, intelligent detector, control module and multi-wire control panel) Features and Benefits :
|
Intelligent Reflective Beam Detector |
|
Item Code: I-9105R I-9105R Intelligent Reflective Beam Detector works on the principle of reflective infrared beam smoke detector that can be directly connected to a fire alarm loop. Transmitting status information via the loop between the detector and controller. The detector must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector. Built-in intelligent microprocessor, the detector has strong ability of analysis and judgment. The detector automatically carries out system adjustment, compensation and variation of ambient data. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. The detector is ideally suited to historical buildings, warehouses,large storages, shopping malls, leisure centres, exhibition halls, , printing houses, clothing factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist.
|
Addressable 1 Loop Fire Panel |
|
We offer Addressable 1 Loop Fire Panel GTS-M200 UL Listed. The GST M200 single loop addressable fire detection control panel is packed with features that are not usually associated with smaller systems. The GST M200 provides a high quality solution at exceptional value. By utilizing advanced GST Protocol, the system is compatible with the complete range of GST intelligent detectors, Sounders, Call Points, Interfaces, including intrinsically safe and gaseous extinguishing control. The GST M200 is manufactured and certified to UL 864 Standard Control Units and Accessories for Fire Alarm System. The GST programming facilities via key pad enables advanced and complex cause and effects to be programmed with ease, cascade evacuation scenario. The GST M200 semi flush-mounted, unique design for modern technology, flexible configuration and easy to operate and commissioning making ideal product for electrical installer. Suitable for small establishment such as small offices, shops,restaurants, bars, libraries, supermarkets, transformer substations etc. Intelligent Fire Alarm Control Panel GST-M200
|
Addressable Single Input Output Module |
|
Item Code: I9301 Intelligent addressable input/output module. A single volt free relay with N/O and N/C change over contacts that can be driven via the fire alarm loop. Commonly used for overriding equipment such as AHU’s,Smoke extracts, Lift returns, auto dialer, BMS, etc. The input can be linked through a volt free contact switch output of ancillary equipment reporting to the fire alarm controller. According to the pre-inputted cause and effects interface programming, the alarm controller sends out a start command to the equipment required to start. After receiving the command, the module activates its relay to change state. Once the equipment under control has operated a confirmation signal can be sent back to the fire alarm controller. Electronic addressing can be done through Hand held Programming tool (P-9910B), purchased separately
|
Intelligent Optical Dual Heat Detector |
|
Intelligent Optical Dual Heat Detector is extremely reliable for application in places where may have high dust levels or smoky environments, making a normal smoke detector unsuitable , for example boiler/plant room, car sparks, kitchen, loading bays, furnace/kiln rooms. Meet the sensitivity requirement of UL 521 Standard for Heat Detectors for Fire Protective Signaling System. Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. Using the thermistor sensor,the unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Drift compensation, Self Diagnosis and history log. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Electronic addressing can be done through Hand held Programming device (P-9910B), purchased separately.
|
Intelligent Dual Heat Detector |
|
Item Code: I-9103-1 Intelligent Dual Heat Detector is extremely reliable for application in places where may have high dust levels or Smokey environments, making a normal smoke detector unsuitable , for example boiler/plant room,cars parks, kitchen, loading bays, furnace/kiln rooms. Meets the sensitivity requirement of EN 54 part 5 European Standard and approved by Loss Prevention Certificate Board (LCPB).Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Self Diagnosis and history log. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. The integral microprocessor analysis the digital signal converted from an alogue Electronic addressing can be done through Hand held Programming device (P-9910B), purchased separately.
|